Available for the Italian Market
LMG Green LMG 60 2-Cycles is a pre-owned industrial distillation system with a special 2-cycle configuration, automatic loading, induction heating and additional equipment. The unit is offered by PU Consulting AB for the Italian market.
This LMG 60 unit is offered by PU Consulting AB for refurbishment, engineering evaluation, research and development, process development or other industrial applications.
Product Information
Manufacturer: LMG GREEN Srl
Model: LMG 60
Serial number: 01230012
Seller: PU Consulting AB
Configuration: Special 2-cycle configuration
Automatic cycles: 2
Cycle control: Standard automatic configuration for 2 cycles, without additional cycle-selection control
Heating technology: Induction heating (CU), as stated on the original purchase invoice
Condenser: Copper condenser
Capacity: 60 litres
Automatic loading: Yes
ATEX: ATEX 3G Zone 2, as stated on the original purchase invoice
Condition: Pre-owned; currently non-operational for water distillation
Potential applications: Water recycling, solvent recovery and industrial distillation
Included Equipment
The original purchase invoice for this specific unit, serial number 01230012, identifies the following equipment and accessories:
- LMG 60 induction distillery Equipment with copper condenser
- Automatic loading system
- Stainless steel reservoir for changing bags
- Heat-resistant bags
- Manual hydraulic scissor table
- Wooden cage
The equipment listed above is based on the original purchase invoice and should be verified against the actual equipment supplied with the machine.
Equipment History
Prior to delivery, laboratory testing was carried out and documented using process water supplied by the original customer.
Based on the available project documentation, the expected production capacity for the LMG 60 without the additional PLC configuration was specified as up to 120 litres of distilled water per 24 hours.
During operation at the customer’s facility, the unit did not achieve the expected water distillation performance under the operating conditions encountered.
According to the available project documentation, the supplier’s technical specialist worked together with the customer for approximately one year to evaluate the installation, perform troubleshooting, rebuild parts of the system and replace components in an effort to achieve the specified operating performance.
Despite these efforts, the unit was not successfully returned to operational service for water distillation.
The equipment is therefore offered as a pre-owned system in its current condition.
Documentation
Available documentation includes:
- Original purchase invoice identifying the machine configuration and serial number
- CE certificate
- ATEX certificate
- Operating manual in English
- Operating manual in Swedish
- Other available original equipment documentation
The available documentation should be reviewed by prospective purchasers as part of their own technical, safety and regulatory assessment.
Important Technical Information
The 2-cycle configuration is based on the actual equipment configuration and available technical information for this specific unit.
The original purchase invoice identifies this specific unit as an LMG 60 induction (CU) configuration with a copper condenser, 60-litre capacity, automatic loading and ATEX 3G Zone 2 classification.
The 2-cycle configuration does not include the additional PLC and cycle-selection control specified for the separate 3-cycle configuration.
This LMG Green LMG 60 2-Cycles unit is configured for two automatic distillation cycles.
The available operating documentation should be reviewed by the purchaser to verify the actual heating configuration and technical characteristics of this specific machine.
PU Consulting AB has not independently verified the complete technical basis underlying the manufacturer’s technical descriptions or the available CE and ATEX documentation, including the extent of testing, assessment or conformity evaluation relating to specific solvents, operating conditions, heating components or hazardous-area applications.
The equipment is therefore offered strictly as-is, where-is.
Prospective purchasers are responsible for carrying out their own technical, safety and regulatory assessment before commissioning or operating the equipment.
Potential Applications
The unit may be of interest for:
- Industrial refurbishment
- Engineering evaluation
- Research and development
- Process development
- Pilot or experimental projects
- Water recycling
- Solvent recovery
- Industrial distillation
- Spare-parts recovery
Italian Market – Technical and Regulatory Assessment
The equipment is offered to potential industrial purchasers in the Italian market.
The purchaser should independently assess the applicable Italian and EU requirements for the intended application, installation environment and process.
Where required, prospective purchasers may consult qualified Italian technical professionals and the relevant Italian authorities regarding applicable technical, environmental, safety, ATEX, electrical and other regulatory requirements.
Contact PU Consulting AB
For pricing, photographs, documentation or technical information about the LMG Green LMG 60 – Special 2-Cycle Configuration, please contact PU Consulting AB.
Prospective buyers are encouraged to provide information about the intended material, required production capacity, process and installation environment so that the potential suitability of the equipment can be discussed.
The equipment is available immediately.
Disclaimer
The equipment is offered by PU Consulting AB on an “as-is, where-is” basis in its current condition.
This pre-owned LMG Green LMG 60 is offered for resale by PU Consulting AB in its current condition. The equipment is identified by its original manufacturer, model and serial number. Product specifications and technical information are based on the available original purchase and project documentation.
Statements concerning manufacturer specifications, technical characteristics, configuration, expected capacity or other technical information are based on available manufacturer, purchase or project documentation and have not necessarily been independently verified by PU Consulting AB.